Specifications |
EIB 2391 S |
Functional safety |
Depending on the connected encoder and subsequent electronics, suited for applications up to
|
PFH |
26 x 10–9 (with respect to an application height of ≤ 1 000 m above sea level) |
Safe position |
Determined by the connected encoder and the subsequent electronics (for example by the configuration); the EIB has no influence on the safe position |
Input |
|
Interface |
EnDat 2.2 |
Ordering designation |
EnDat22 |
Electrical connection |
M12 connector (female), 8-pin |
Power supply of encoder (UP2) |
5.1 V DC ± 0.15 V, max. 2500 mW |
Cable length |
≤ 100 m1) |
Output |
|
Interface |
DRIVE-CLiQ |
Ordering designation |
DQ01 |
Electrical connection |
M12 connector (male), 8-pin |
Cable length |
≤ 95 m2) |
Power supply (UP1) |
24 V DC (16.0 V to 28.8 V) |
Power consumption |
Maximum With 16.0 V: ≤ 4.1 W Typical With 24 V: 1.1 W + 1.15 x PMtyp (where PMtyp = typical power consumption of encoder) |
Operating temperature |
0 °C to 60 °C |
Storage temperature |
–30 °C to 70 °C |
Vibration 55 to 2000 Hz Shock 11 ms |
100 m/s2 (IEC 60 068-2-6) 200 m/s2 (IEC 60 068-2-27) |
Protection |
IP 65 |
Weight |
Approx. 180 g |
1) With HEIDENHAIN cable; note the power supply at the encoder. 2) Depending on the output cable; the plug connection to the EIB is to be considered a DRIVE-CLiQ coupling. |